Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1551622.015 - Ocenco, Incorporated

Inspection Information - Office: Milwaukee Area Office

 

Inspection Nr: 1551622.015
Report ID: 0523400
Date Opened: 09/07/2021

Site Address:
Ocenco, Incorporated
10225 82nd Ave
Pleasant Prairie, WI 53158

Mailing Address:
10225 82nd Ave, Pleasant Prairie, WI 53158

Union Status: NonUnion

SIC:

NAICS: 339113/Surgical Appliance and Supplies Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/07/2021

Emphasis:

Case Closed: 12/18/2023


Related Activity
Type Activity Nr Safety Health
Referral 1807651 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 1 1
Initial Penalty $22,479 $0 $0 $0 $0 $22,479
Current Penalty $6,164 $0 $0 $0 $0 $6,164
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C01 02/17/2022 03/23/2022 $6,164 $6,164 $0 I - Informal Settlement  
2. 01002 Serious 19100307 B 02/17/2022 03/16/2022 $0 $6,164 $0 I - Informal Settlement Citation has been deleted.
3. 01003 Serious 19100307 C02 I 02/17/2022 03/16/2022 $0 $10,151 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 142172.015
Event: 09/07/2021
Employee burns, bruises abdomen when oxygen system explodes

At 6:55 a.m. on September 7, 2021, an employee working for a surgical supply manufacturer was filling multiple compressed oxygen cylinders from a pressurized bulk system. An explosion occurred blowing out a portion of braided hose and copper piping. Pressurized gas was released along with flying shrapnel from the blast. The employee was struck by the flying debris and hospitalized to treat burns and contusions to his abdomen.

Keywords: Abdomen, Burn, Compressed Gas, Contusion, Cylinder, Explosion, Filling, Filling Station, Flying Object, Gas, Hose, Lockout, Lockout/Tagout, Metal Pipe, Oxygen, Shrapnel, Storage Area, Struck By

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1551622.015 60 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close