Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1549884.015 - Aulfab, Llc

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 1549884.015
Report ID: 0524700
Date Opened: 08/26/2021

Site Address:
Aulfab, Llc
1018 Matzinger Rd.
Toledo, OH 43612

Mailing Address:
1018 Matzinger Rd., Toledo, OH 43612

Union Status: NonUnion

SIC:

NAICS: 332999/All Other Miscellaneous Fabricated Metal Product Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/26/2021

Emphasis: N:Amputate

Case Closed: 11/16/2021


Related Activity
Type Activity Nr Safety Health
Referral 1802077 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $4,096 $0 $0 $0 $0 $4,096
Current Penalty $2,850 $0 $0 $0 $0 $2,850
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A03 II 09/27/2021 $2,850 $4,096 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 138562.015
Event: 08/13/2021
Employee fractures four fingers while operating press brake,

At 11:00 a.m. on August 13, 2021, an employee, on his first day of work, was operating a press brake to bend inner support parts. While using an electronic foot pedal to control the press brake, the employee positioned his hand below the light curtain to adjust a part. Activating the foot pedal caused the press to lower, trapping his four fingers in the press ram. The employee, despite wearing cut-proof gloves, sustained severe injuries, including four broken fingers, three of which required pins. Approximately one week later, the tip of the employee's left middle finger was surgically removed down to the first knuckle. Contributing factors may have included improperly adjusted light curtains, inoperable two-hand controls, working position, and lack of experience. The employee was hospitalized for treatment.

Keywords: Amputated, Brake, Finger, Fingertip, Foot Control, Foot pedal, Foot-Powered Press, Fracture, Hand, Knuckle, Light Curtain, Press Brake, Surgical Amputation, Trapped

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1549884.015 21 M Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.