Inspection Detail
Inspection: 1548045.015 - 112215 - Forest River Inc
Inspection Information - Office: Indiana Department Of Labor
Site Address:
112215 - Forest River Inc
712 Eisenhower Drive South
Goshen, IN 46526
Mailing Address:
900 Co. Rd. 1, Elkhart, IN 46515
Union Status: NonUnion
SIC:3716
NAICS: 336213/Motor Home Manufacturing
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/20/2021
Emphasis:
Case Closed: 03/22/2022
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1798010 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 3 | ||||
Current Violations | 3 | 3 | ||||
Initial Penalty | $21,000 | $0 | $0 | $0 | $0 | $21,000 |
Current Penalty | $7,000 | $0 | $0 | $0 | $0 | $7,000 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100332 B02 | 12/30/2021 | 02/03/2022 | $3,500 | $7,000 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100333 B02 | 12/30/2021 | 02/03/2022 | $3,500 | $7,000 | $0 | I - Informal Settlement | ||
3. | 01003 | Serious | 19100335 A01 I | 12/30/2021 | 02/03/2022 | $0 | $7,000 | $0 | I - Informal Settlement |
Investigation Summary
At 11:00 a.m. on August 12, 2021, an employee, Coworker #1 (Line Supervisor) and Coworker #2 (Group Leader) were troubleshooting issues with a Class A Recreational Vehicle (RV) Station Unit on the north side of a plant. The unit generator and the A/C unit was not running but the display console inside the RV showed the A/C was running. Coworker #2 turned off the generator from inside the unit and Coworker #1 disconnected the panel switch from the 12-volt power cable. They both left the RV unit but left the RV running while Coworker #2 notified the employee to work on the unit and wire up the generator. The employee was working on the driver-side cargo compartment with the second compartment down. The wires consist of 2 120 volts live wires connected to a 30 ampere breaker, two neutral white wires that complete the circuit and a green ground wire that connects to the chassis. Coworker #3 came on site 5 minutes later and found the employee had been killed, most likely after being electrically shocked.
Keywords: Air Conditioner, Battery, Electric Generator, Electric Shock, Electric current, Electrical, Electrical Wire, Hand, Lack of Engineering Controls, Motor Vehicle, Shock, Troubleshooting
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1548045.015 | 31 | F | Fatality | Occupation not reported |