Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1547130.015 - Plas-Tec Corp.

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 1547130.015
Report ID: 0524700
Date Opened: 08/11/2021

Site Address:
Plas-Tec Corp.
601 W. Indiana St.
Edon, OH 43518

Mailing Address:
601 W. Indiana St., Edon, OH 43518

Union Status: NonUnion

SIC:

NAICS: 326199/All Other Plastics Product Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/11/2021

Emphasis:

Case Closed: 01/12/2022


Related Activity
Type Activity Nr Safety Health
Referral 1795060 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $19,114 $0 $0 $0 $0 $19,114
Current Penalty $9,557 $0 $0 $0 $0 $9,557
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100332 B01 09/27/2021 10/06/2021 $4,779 $9,557 $0 I - Informal Settlement  
2. 01001B Serious 19100333 A 09/27/2021 10/26/2021 $0 $0 $0 I - Informal Settlement  
3. 01002 Serious 19100335 A01 I 09/27/2021 10/06/2021 $4,779 $9,557 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 138036.015
Event: 08/05/2021
Employee sustains electrical shock when reaching into contro

At 1:10 p.m. on August 5, 2021, an employee working as a production supervisor for a plastics products manufacturer was preparing a plastic injection molding machine for startup. The employee discovered that the temperature was low on a portion of the heat barrel. He opened the electrical panel to access the part of the controller that adjusts the temperature. The temperature controller was located within the 480V electrical panel directly adjacent to a bank of fuses. In the process of pressing the buttons on the controller, the employee contacted live parts within the panel causing him to be shocked. The force of the electrical shock threw the employee backwards away from the panel. There were no witnesses to the incident. The employee was hospitalized to treat multiple injuries due to the electrical shock.

Keywords: Conductor, Current, Electric Shock, Electric current, Electrical Wire, Electrical panel, Engineering Controls, Hand, Lack of Engineering Controls, Machine Guarding, Machine operator, Manufacturing, Plastic Mfg, Production Line, Reaching In, Shock, Supervisor, Thrown

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1547130.015 49 M Hospitalized injury Supervisors, production occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.