Inspection Detail
Inspection: 1546530 - Consolidated Foundry Inc
Inspection Information - Office: Austin Area Office
Site Address:
Consolidated Foundry Inc
5610 Fm 1346
San Antonio, TX 78220
Mailing Address:
Mr Larry Key V P, , 00000
Union Status: NonUnion
SIC:3321
NAICS: 0
Inspection Type: Accident
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/25/1984
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 10/01/1985
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360559389 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 3 | 5 | 8 | |||
Current Violations | 3 | 5 | 8 | |||
Initial Penalty | $980 | $0 | $0 | $0 | $0 | $980 |
Current Penalty | $595 | $0 | $0 | $0 | $0 | $595 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 19100219 D01 | 05/15/1984 | 05/24/1984 | $150 | $210 | $0 | I - Informal Settlement | ||
2. | 01001B | Serious | 19100219 E03 I | 05/15/1984 | 05/24/1984 | $0 | $0 | $0 | - | ||
3. | 01002 | Serious | 19100304 F04 | 05/15/1984 | 05/18/1984 | $200 | $280 | $0 | I - Informal Settlement | ||
4. | 01003 | Serious | 5A0001 | 05/25/1984 | 06/05/1984 | $245 | $490 | $0 | 06/14/1984 | F - Formal Settlement | |
5. | 02001 | Other | 19100023 D01 I | 05/15/1984 | 05/24/1984 | $0 | $0 | $0 | - | ||
6. | 02002 | Other | 19100151 B | 05/15/1984 | 05/24/1984 | $0 | $0 | $0 | - | ||
7. | 02003 | Other | 19100178 L | 05/15/1984 | 06/11/1984 | $0 | $0 | $0 | - | ||
8. | 02004 | Other | 19100178 P01 | 05/15/1984 | 06/11/1984 | $0 | $0 | $0 | - | ||
9. | 02005 | Other | 19100243 B01 | 05/15/1984 | 05/24/1984 | $0 | $0 | $0 | - |
Investigation Summary
A maintenance supervisor was repairing an electrical problem in a Halbert 2.7-metric-ton overhead crane. The crane was not equipped with a circuit breaker that could be locked in the open position, nor was the circuit deenergized before he began work. The employee contacted energized parts on a 480-volt transformer while he was standing on a metal walkboard on a rubber-tired mobile scaffold. The scaffold was grounded through the bridge rails. The employee was electrocuted.
Keywords: REPAIR, E GI IV, ELECTRICAL, ELECTROCUTED, ELECTRICAL WORK, LOCKOUT, OVERHEAD CRANE, TRANSFORMER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1546530 | Fatality | Electric Shock | Supervisors, mechanics and repairers |