Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1544152.015 - American Tool And Die, Inc.

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 1544152.015
Report ID: 0524700
Date Opened: 07/27/2021

Site Address:
American Tool And Die, Inc.
2024 Champlain Street
Toledo, OH 43611

Mailing Address:
2024 Champlain Street, Toledo, OH 43611

Union Status: NonUnion

SIC:

NAICS: 332999/All Other Miscellaneous Fabricated Metal Product Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/27/2021

Emphasis: N:Amputate

Case Closed: 07/25/2022


Related Activity
Type Activity Nr Safety Health
Referral 1789281 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $15,214 $0 $0 $0 $0 $15,214
Current Penalty $7,802 $0 $0 $0 $0 $7,802
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C01 08/31/2021 11/15/2021 $1,775 $2,926 $0 I - Informal Settlement  
2. 01002 Serious 19100217 B07 III 08/31/2021 $2,009 $4,096 $0 I - Informal Settlement  
3. 01003 Serious 19100217 C03 I B 08/31/2021 10/01/2021 $2,009 $4,096 $0 I - Informal Settlement  
4. 01004 Serious 19100217 E01 08/31/2021 10/01/2021 $2,009 $4,096 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 137521.015
Event: 07/20/2021
Employee?s fingers are amputated and crushed while resetting

At 11:00 a.m. on July 20, 2021, Employee #1 was piercing metal parts on a Bliss 60-ton partial revolution press when he was resetting the press at the control panel. After removing his right-hand restraint and switching the press to inch mode, he did not reapply the restraint and placed his right hand into the point of operation while setting a part in place. His foot accidentally actuated the pedal, cycling the press. Employee #1 sustained a complete amputation of his right middle finger, a partial amputation of his right index finger to the second knuckle, and his right ring finger was crushed and pierced, requiring surgery. Factors that may have contributed include lack of engineering controls, supervision, and training. He was hospitalized for treatment.

Keywords: Amputation, Crushed, Finger, Fingertip, Foot pedal, Insufficient Supervision, Knuckle, Lack of Engineering Controls, Partial Amputation, Point Of Operation, Press, Untrained

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1544152.015 59 M Non Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close