Inspection Detail
Inspection: 1539533.015 - Express Services, Inc.
Inspection Information - Office: Dallas Area Office
Site Address:
Express Services, Inc.
320 Fm 316
Eustace, TX 75124
Mailing Address:
5609 S. Donnybrook Ave, Tyler, TX 75703
Union Status: NonUnion
SIC:
NAICS: 561311
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/01/2021
Emphasis:
Case Closed: 10/08/2021
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1781956 |
Investigation Summary
At 10:15 a.m. on June 29, 2021, an employee was assisting a coworker changing out fluorescent lights for LED lighting and installing acoustic ceiling panels. While the employee was hanging panels, he was standing on a 30 inch wide non-motorized mobile scaffold 4 feet off the ground. The coworker turned to reach for another panel and reported that when he turned back toward the employee, the employee had fallen and struck his head on the floor and was killed.
Keywords: Blunt force, Blunt force trauma, Concussion, Fall, Fall Protection, Head, Installing, Maintenance, Mobile Scaffold, Multi-employer Worksite, Multiemployer, Scaffold, Scaffolding, Struck Against, Temporary Worker, Unstable Position
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1539533.015 | 44 | M | Fatality | Occupation Not Listed |