Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1533620.015 - Cf&I Steel, L.P.

Inspection Information - Office: Englewood Area Office

 

Inspection Nr: 1533620.015
Report ID: 0830600
Date Opened: 05/30/2021

Site Address:
Cf&I Steel, L.P.
2100 South Freeway
Pueblo, CO 81004

Mailing Address:
1612 E. Abriendo, Pueblo, CO 81004

Union Status: Union

SIC:

NAICS: 332312/Fabricated Structural Metal Manufacturing


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/18/2021

Emphasis:

Case Closed: 03/01/2022


Related Activity
Type Activity Nr Safety Health
Accident 1772536
Inspection 1534359 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $40,959 $0 $0 $0 $0 $40,959
Current Penalty $40,959 $0 $0 $0 $0 $40,959
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 11/19/2021 01/10/2022 $13,653 $13,653 $0 I - Informal Settlement  
2. 01002 Serious 5A0001 11/19/2021 01/10/2022 $13,653 $13,653 $0 I - Informal Settlement  
3. 01003A Serious 19100120 Q01 11/19/2021 01/10/2022 $13,653 $13,653 $0 I - Informal Settlement  
4. 01003B Serious 19100120 Q02 IX 11/19/2021 02/28/2022 $0 $0 $0 I - Informal Settlement  
5. 01003C Serious 19100120 Q02 XI 11/19/2021 01/10/2022 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 135918.015
Event: 05/29/2021
Three employees sustain multiple burns in furnace explosion

At 5:00 p.m. on May 29, 2021, Employee #1, a maintenance worker, Employee #2, an electrician, and Employee #3, a heat treat worker, were monitoring an electric arc furnace after replacing a cooling panel. Water from the cooling panel leaked into the furnace and caused an explosion. Employee #1 was hospitalized to treat burns to his face and torso. Employee #2 was hospitalized to treat burns to his torso and respiratory system. Employee #3 was hospitalized to treat burns to his torso and respiratory system.

Keywords: Burn, Electrician, Engineering Controls, Exploded, Face, Fire, Furnace, Heat, High Temperature, Inhalation, Inspecting, Inspection, Lack of Engineering Controls, Machine operator, Maintenance, Melting Furnace, Replace, Respiratory, Respiratory Tract, Struck By, Torso, Unsafe Position, Water

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1533620.015 26 M Hospitalized injury Machinery maintenance occupations
2 1533620.015 43 M Hospitalized injury Electricians
3 1533620.015 59 M Hospitalized injury Heat treating equipment operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.