Powered by GoogleTranslate

Inspection Detail

Inspection: 15320187 - Call Burn Up & Sims Inc (Cbs)

Inspection Information - Office: Pr-E-Arecibo 0257210

 

Inspection Nr: 15320187
Report ID: 0257210
Date Opened: 09/18/1984

Site Address:
Call Burn Up & Sims Inc (Cbs)
Bd Sabana Seca 1 Esq 2 Villa Evangelina
Manati, PR 00701

Mailing Address:
Po Box 2539, Bagamon, PR 00619

Union Status: NonUnion

SIC:3661

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/19/1984

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/05/1985


Related Activity
Type Activity Nr Safety Health
Accident 360596605
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 5 7
Current Violations 2 5 7
Initial Penalty $1,600 $0 $0 $0 $0 $1,600
Current Penalty $1,600 $0 $0 $0 $0 $1,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100268 B07 11/27/1984 11/30/1984 $700 $700 $0 -  
2. 01002 Serious 19100268 C 11/27/1984 12/30/1984 $900 $900 $0 -  
3. 02001 Other 19030002 A01 11/27/1984 12/01/1984 $0 $0 $0 -  
4. 02002 Other 19040002 A01 11/27/1984 12/07/1984 $0 $0 $0 -  
5. 02003 Other 19040002 A02 11/27/1984 11/30/1984 $0 $0 $0 -  
6. 02004 Other 19040004 11/27/1984 12/07/1984 $0 $0 $0 -  
7. 02005 Other 19040005 A 11/27/1984 11/30/1984 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14461701
Event: 09/12/1984
ELECTRIC SHOCK - DIRECT CONTACT WITH OVERHEAD LINE

An employee was installing a telephone at a residence. He was working on the roof of the two-story home, removing a black cable box. When the employee stood up, he contacted an 8320-volt overhead power line with his neck and was electrocuted.

Keywords: OVERHEAD POWER LINE, ROOF, ELECTRICAL, TELECOM WORK, E TC, ELECTROCUTED, NECK, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 15320187 Fatality Electric Shock Telephone line installers and repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close