Powered by GoogleTranslate

Inspection Detail

Inspection: 15311103 - Ecolab Pest Control

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 15311103
Report ID: 0453710
Date Opened: 01/02/1990

Site Address:
Ecolab Pest Control
120 East Pine Street
Graham, NC 27253

Mailing Address:
P.O. Box 1089, Graham, NC 27253

Union Status: NonUnion

SIC:7342

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/08/1990

Emphasis:

Case Closed: 03/27/1991


Related Activity
Type Activity Nr Safety Health
Accident 360487862
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100134 B01 02/07/1990 02/14/1990 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 943571
Event: 11/10/1989
EMPLOYEES BURNED IN EXPLOSION

Two employees were applying pesticides to the ceiling area of a fast-food establishment. One employee was drilling holes in the ceiling, and the other employee was spraying Drione dust pesticide through the ceiling holes by means of a pressurized unit (a steel container pressurized at 0-5.3 pascals gauge, a hose with a used nozzle, and a safety pop-off valve). The container had been pressurized with pure oxygen. The dust passing through the system caused a buildup of static electricity. A static electrical discharge combined with the oxygen caused the container to explode, burning both employees. Employee #1 was hospitalized for 2 weeks. Employee #2 was hospitalized for 18 days.

Keywords: BURN, OXYGEN, STATIC ELECTRICITY, ELECTRICAL, EXPLOSION, COMBUSTIBLE DUST

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 15311103 Hospitalized injury Burn/Scald(Heat) Pest control occupations
2 15311103 Hospitalized injury Other Pest control occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.