Inspection Detail
Inspection: 15305923 - Baxter-Travenol Laboratories Inc
Inspection Information - Office: Nc Department Of Labor - Raleigh
Site Address:
Baxter-Travenol Laboratories Inc
Hwy 221 North
Marion, NC 28752
Mailing Address:
P O Box 1390, Marion, NC 28752
Union Status: NonUnion
SIC:2834
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/28/1986
Emphasis:
Case Closed: 07/28/1986
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360767107 |
Investigation Summary
EMPLOYEE #1 WAS SERIOUSLY INJURED WHEN THE DOOR OF AN AUTOCLAVE BLEW OFF DURING THE START UP CYCLE (UNLOADED) OF AN EQUIPMENT CHECK. EMPLOYEE #1 WAS MERELY PASSING THROUGH THE STERILIZING DEPARTMENT AND WAS 50 FEET AWAY FROM THE AUTOCALVE WHEN THE DOOR BLEW OFF. SUBSEQUENT INVESTIGATION REVEALED THAT THE DOOR WAS NOT FULLY SECURED BEFORE IT WAS PRESSURIZED. THE LOCKING MECHANISM WAS MISALIGNED, IN THAT THE SERIES OF ROLLERS DOWN EACH SIDE OF THE DOOR DID NOT LINE UP CORRECTLY WITH THE DOOR LUG STRIKER PLATES. AS THE INTERNAL PRESSURE INCREASED, THE PARTIALLY SECURED DOOR SLID PAST THE PLATES AND BLEW ACROSS THE ROOM.
Keywords: PRESSURE VESSEL, UNSECURED, HIGH PRESSURE, STRUCK BY, FLYING OBJECT, DOOR
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 15305923 | Hospitalized injury | Other | Industrial machinery repairers |