Inspection Detail
Inspection: 1524875.015 - Johnson Electric Coil Co., Inc.
Inspection Information - Office: Appleton Area Office
Site Address:
Johnson Electric Coil Co., Inc.
821 Watson Street
Antigo, WI 54409
Mailing Address:
821 Watson Street, Antigo, WI 54409
Union Status: NonUnion
SIC:
NAICS: 334416/ Electronic Coil, Transformer, and Other Inductor Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 04/13/2021
Emphasis:
Case Closed: 05/13/2021
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1753482 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $4,642 | $0 | $0 | $0 | $0 | $4,642 |
Current Penalty | $2,437 | $0 | $0 | $0 | $0 | $2,437 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100212 A01 | 04/22/2021 | 06/18/2021 | $2,437 | $4,642 | $0 | I - Informal Settlement |
Investigation Summary
At 11:00 a.m. on April 5, 2021, Employee #1, a 63-year-old male, was operating a #145 GMC shear to cut glastic in the Material Prep area. The shear was foot pedal actuated, with the pedal connected to a flexible cord that allowed the operator to position it to their preference. The shear blade was 4 feet long and was equipped with a yellow hold down clamp that would move downward to hold the material in place before the shear blade engaged. However, there was no fence guard or other safety mechanism to prevent access to the gap underneath the clamp during the hazardous motion. At the time of the incident, the clamp was set 3/8 inch from the material rest. Employee #1 was cutting a 1/16-inch thick piece of glastic, measuring 3.625 inches by 5 inches. Initially, the employee had used a scrap piece of material to position the piece, but then used both hands to hold it in place. As the hold down clamp came down, it pinched the employee's left middle finger, amputating the tip of the bone and padding. The employee was treated without hospitalization.
Keywords: Amputated, Amputation, Broken Bone, Clamp, Finger, Fingertip, Hold-Down Clamp, Pinch Point, Pinched, Shear
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1524875.015 | 63 | M | Non Hospitalized injury | Laborers, except construction |