Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1523660.015 - Patterson Pump Company

Inspection Information - Office: Atlanta East Area Office

 

Inspection Nr: 1523660.015
Report ID: 0418100
Date Opened: 04/07/2021

Site Address:
Patterson Pump Company
2129 Ayersville Rd
Toccoa, GA 30577

Mailing Address:
2129 Ayersville Rd, Toccoa, GA 30577

Union Status: NonUnion

SIC:

NAICS: 333914 


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/07/2021

Emphasis: N:Amputate

Case Closed: 06/23/2021


Related Activity
Type Activity Nr Safety Health
Referral 1751391 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $24,870 $0 $0 $0 $0 $24,870
Current Penalty $17,409 $0 $0 $0 $0 $17,409
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100151 C 05/26/2021 06/22/2021 $5,803 $8,290 $0 I - Informal Settlement  
2. 01002 Serious 19100179 N03 I 05/26/2021 06/22/2021 $5,803 $8,290 $0 I - Informal Settlement  
3. 01003 Serious 19100252 B02 III 05/26/2021 06/22/2021 $5,803 $8,290 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 135151.015
Event: 03/29/2021
Employee amputates finger when caught between pump and sling

At 11:15 a.m. on March 29, 2021, Employee #1 was assisting in prepping a vertical turbine pump that was 17.5 feet long and weighed 7,137 pounds. Employee #1 was responsible for guiding the crane operator, who was utilizing a 10-ton gantry crane to place the pump into the "V" shaped in-house manufactured cradles. The vertical turbine pump was turned counterclockwise, which caused the pump shaft to retract into the column assembly, which caused the pump to become unstable in the cradles. The pump shifted toward Employee #1, which caused the employee's hand to get caught in between the pump and the sling. Employee #1 amputated his right-hand middle finger and was treated without hospitalization.

Keywords: Amputated, Amputation, Caught Between, Crane, Finger, Gantry Crane, Pump, Site Preparation , Sling, Unstable Load

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1523660.015 25 M Non Hospitalized injury Welders and cutters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close