Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1522867.015 - Plascore Inc

Inspection Information - Office: Miosha General Industry Safety & Health Division

 

Inspection Nr: 1522867.015
Report ID: 0552652
Date Opened: 03/31/2021

Site Address:
Plascore Inc
615 N Fairview St, P.O. Box 170
Zeeland, MI 49464

Mailing Address:
615 N Fairview St, P.O. Box 170, Zeeland, MI 49464

Union Status: NonUnion

SIC:

NAICS: 332311/Prefabricated Metal Building and Component Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/06/2021

Emphasis: N:Amputate

Case Closed: 04/08/2021


Related Activity
Type Activity Nr Safety Health
Referral 1715400 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 134474.015
Event: 01/06/2021
Employee amputates thumb when struck by blade of fan in cycl

At 5:45 a.m. on January 6, 2021, Employee #1 was checking the air flow coming from under a dust collector system. While attempting to verify the airflow, the employee's right hand was placed under the motor. The employee's right thumb was struck by the blade in the cyclone. The employee was treated without hospitalization for a thumb amputation.

Keywords: Amputated, Amputation, Blade, Dust Collector, Hand, Struck By, Thumb

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1522867.015 57 M Non Hospitalized injury Machinery maintenance occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close