Inspection Detail
Inspection: 1522204.015 - Manitowoc Tool & Machining, Llc
Inspection Information - Office: Appleton Area Office
Site Address:
Manitowoc Tool & Machining, Llc
4211 Clipper Drive
Manitowoc, WI 54220
Mailing Address:
4211 Clipper Drive, Manitowoc, WI 54220
Union Status: NonUnion
SIC:
NAICS: 332710/Machine Shops
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/31/2021
Emphasis: N:Amputate
Case Closed: 09/14/2021
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1750067 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $0 | $0 | $27,033 | $0 | $0 | $27,033 |
Current Penalty | $13,653 | $0 | $0 | $0 | $0 | $13,653 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100212 A01 | 06/30/2021 | $13,653 | $27,033 | $0 | I - Informal Settlement |
Investigation Summary
At approximately 1:00 a.m. on March 25, 2021, an employee was placing a part on the fixture which then would be clamped down prior to operations beginning. The #770-02 Mazak Mega Turn 900S CNC turning machine had recently been installed and was used in production for two to three weeks to manufacture one part. The employee would place the part weighing approximately 34 pounds onto the horizontal fixture, which had three clamps to secure the part. The clamps were activated with a foot pedal and would apply between 110-120 psi of pressure. At the time of the incident, the employee placed the part onto the fixture and activated the foot pedal while his hand was resting on the part. His left ring finger was located in the direction of travel of the clamp and was caught between the clamp and part. The employee activated the foot pedal to release the clamp and removed his hand/finger from the part. The employee amputated his left-hand ring finger and was hospitalized.
Keywords: Amputated, Amputation, Caught Between, Finger, Foot pedal, Hold-Down Clamp
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1522204.015 | 63 | M | Non Hospitalized injury | Machine operators, not specified |