Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1521163.015 - Engie North America Inc.

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 1521163.015
Report ID: 0751910
Date Opened: 03/23/2021

Site Address:
Engie North America Inc.
Corner Of West Burlington St. & Front St.
Iowa City, IA 52242

Mailing Address:
640 South Madison St Attn: Nicole Knapp, Iowa City, IA 52242

Union Status: NonUnion

SIC:

NAICS: 221112/Fossil Fuel Electric Power Generation


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 06/03/2021

Emphasis: N:Amputate, S:Amputate

Case Closed: 07/23/2021


Related Activity
Type Activity Nr Safety Health
Referral 1746718 Yes Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1
Initial Penalty $12,145 $0 $0 $957 $0 $13,102
Current Penalty $0 $0 $0 $11,500 $0 $11,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100147 C04 I 06/11/2021 07/08/2021 $11,500 $12,145 $0 I - Informal Settlement  
2. 02001 Other 19040040 A 06/11/2021 $0 $957 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 134253.015
Event: 03/16/2021
Employee's finger is amputated in belt and pulley

At 8:05 a.m. on March 16, 2021, Employee #1 and a coworker were performing maintenance on a fan. They began with running the fan at both speeds to diagnose what the problem was. Next, they removed the top housing, which guarded the belt and pulley, and ran the fan at both speeds to continue their diagnostics. They then decided to remove the belt. The coworker turned the fan off with the controls and opened the disconnect. The belt and pulley continued to rotate after the fan was shut down. Employee #1 was standing on top of the top housing near the belt and pulley and his finger was pulled into the belt and pulley and the tip amputated. Employee #1 was treated without hospitalization.

Keywords: Amputated, Amputation, Belt, Caught Between, Disconnecting Means, Fan, Finger, Fingertip, Maintenance, Pulled In, Pulley, Rotating Parts, Unguarded

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1521163.015 63 M Non Hospitalized injury Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close