Inspection Detail
Inspection: 15196470 - Utex Oil Co
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
Utex Oil Co
Altamont Plant 3 Miles Of West Of
Altamont, UT 84001
Mailing Address:
C/O Ken Chapman Po Box 120, Altamont, UT 84001
Union Status: NonUnion
SIC:2911
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/29/1984
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 08/29/1984
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360601389 |
Investigation Summary
One of two jack screws on the suction valve of a unit worked loose. Because it was under 500 pounds per square inch of pressure, the valve eventually blew out of position. This left a 1-inch hole through which methane gas could leak into the refrigeration and compressor building. The gas was apparently ignited by the hot exhaust manifold (between 500 and 1200 degrees) on the unit's blower engine. The exhaust manifold was located 6 feet from the gas leak. All building operations could be shut down from the outside. However, Employee # 1 entered the building for an unknown reason. He received multiple burns and had to be hospitalized.
Keywords: BURN, NATURAL GAS, EXPLOSION, HIGH PRESSURE, VALVE, GAS LEAK
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 15196470 | Hospitalized injury | Burn/Scald(Heat) | Miscellaneous plant and system operators |
Translate