Inspection Detail
Inspection: 15189285 - Burns & Mcdonnell Engineering
Inspection Information - Office: Utah Division Of Occupational Safety And Health
Site Address:
Burns & Mcdonnell Engineering
1/2 M N 1/4 Mi W Hghy 40 & 208 Jct Tabiona Road
Tabiona, UT 84072
Mailing Address:
Po Box 1169, Vernal, UT 84078
Union Status: NonUnion
SIC:1623
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 06/27/1984
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/27/1984
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360601884 |
Investigation Summary
AN INSPECTOR FOR A POWER LINE CONSTRUCTION FIRM WAS IN CHARGE OF QUALITY CONTROL. WHILE HE WAS PLUMBING A TRANSMISSION TOWER, A CRACKING NOISE COULD BE HEARD COMING FROM THE UPPER PART OF THE TOWER. AS PART OF HIS JOB AS AN INSPECTOR, HE MADE THE 60-FOOT CLIMB UP THE TOWER TO INVESTIGATE. THE ATTACHMENT FOR THE SOUTHEAST GUY WAS SUPPOSED TO HAVE BEEN A 1-INCH UNIT, BUT IT HAD BEEN INSTALLED WITH 1.125-INCH NUTS. CONSEQUENTLY, AS THE TENSION INCREASED, THE UNIT EVENTUALLY SHEARED. THIS OCCURRED WHILE THE EMPLOYEE WAS ON THE TOWER. WHEN THE UNIT SHEARED, THE TOWER ROTATED AND FELL INTO A PARALLEL OVERHEAD POWER LINE. THE EMPLOYEE FELL TO A DIRT ROADWAY BELOW AND WAS KILLED.
Keywords: COLLAPSE, GUY, ELEC UTILITY WORK, FALL, TRANSMISSION TOWER
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 15189285 | Fatality | Other | Construction inspectors |