Powered by GoogleTranslate

Inspection Detail

Inspection: 15145071 - Donnelly Printing Company Inc

Inspection Information - Office: Tennessee Osha Nashville Office - Safety

 

Inspection Nr: 15145071
Report ID: 0454712
Date Opened: 02/24/1986

Site Address:
Donnelly Printing Company Inc
801 Steam Plant Road
Gallatin, TN 37066

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:2759

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/12/1986

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/29/1986


Related Activity
Type Activity Nr Safety Health
Accident 360778229
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $640 $0 $0 $0 $0 $640
Current Penalty $640 $0 $0 $0 $0 $640
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100106 E02 IVD 03/27/1986 04/14/1986 $640 $640 $0 A - Amendment Citation has been deleted.
2. 01001B Serious 19100106 E06 I 03/27/1986 04/14/1986 $640 $0 $0 A - Amendment  
3. 01001C Serious 19100106 E06 II 03/27/1986 04/14/1986 $0 $0 $0 A - Amendment Citation has been deleted.

Investigation Summary

Investigation Nr: 14305882
Event: 02/21/1986
TOLUENE VAPORS IGNITED, BURNING EMPLOYEES

TWO EMPLOYEES, A ROLLTENDER AND ASSISTANT PRESSMAN, WORKING ON LEVEL ONE OF PRINTER #827, WERE POURING TOLUENE FROM TALLOW CANS ONTO THE WEB TO CLEAN THE IDLERS. A SUDDEN EXPLOSION AND RESULTING FIRES OCCURRED. THE TWO EMPLOYEES SUSTAINED SECOND AND THIRD DEGREE BURNS. THE PRESSMAN ON THE THIRD LEVEL OF PRINTER #827 WAS BURNED, AS THE FIRE FOLLOWED THE VAPORS WHICH HAD RISEN TO THE THIRD LEVEL. A HOIST OPERATOR, STANDING NEXT TO PRESS #827, WAS BURNED AS WELL. A ROLLTENDER FROM PRESS #828 WAS BURNED WHEN HE HELPED PUT A FIRE BLANKET ON ONE OF THE BURNED EMPLOYEES. THE FIRE AND EXPLOSION ARE THOUGHT TO BE THE RESULT OF A STATIC SPARK WHICH IGNITED THE TOLUENE VAPORS.

Keywords: BURN, STATIC ELECTRICITY, FLAMMABLE VAPORS, CLEANING, FIRE, TOLUENE, EXPLOSION, SPARK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 15145071 Hospitalized injury Burn/Scald(Heat) Printing machine operators
2 15145071 Hospitalized injury Burn/Scald(Heat) Printing machine operators
3 15145071 Hospitalized injury Burn/Scald(Heat) Hoist and winch operators
4 15145071 Hospitalized injury Burn/Scald(Heat) Printing machine operators
5 15145071 Hospitalized injury Burn/Scald(Heat) Printing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.