Inspection Detail
Inspection: 1510085.015 - Zekelman Industries, Inc.
Inspection Information - Office: Erie Area Office
Site Address:
Zekelman Industries, Inc.
20 Church Street
Wheatland, PA 16161
Mailing Address:
20 Church Street, Wheatland, PA 16161
Union Status: Union
SIC:
NAICS: 331210/Iron and Steel Pipe and Tube Manufacturing from Purchased Steel
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/14/2021
Emphasis:
Case Closed: 12/20/2021
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1717280 | Yes |
Investigation Summary
At 7:30 a.m. on January 8, 2021, Employee #1, employed in crane operation assistance, was signaling to a crane operator during a load release. The crane struck 10-foot tall uprights, also called "pockets," which were used to separate and sort metal pipes. The uprights fell over, striking the worker in the back and causing him to fall forward onto the concrete floor, striking his face. The employee sustained broken vertebrae, a broken nose, and a laceration to his face. Emergency services transported the employee to the hospital for admission and treatment.
Keywords: Concrete Floor, Crane, Face, Falling Object, Fracture, Head, Laceration, Nose, Vertebra
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1510085.015 | 63 | M | Hospitalized injury | Laborers, except construction |