Powered by GoogleTranslate

Inspection Detail

Inspection: 15099617 - Amfac Foods Inc

Inspection Information - Office: Bend

 

Inspection Nr: 15099617
Report ID: 1054115
Date Opened: 09/20/1984

Site Address:
Amfac Foods Inc
Westland Rd
Hermiston, OR 97838

Mailing Address:
Po Box 705, Hermiston, OR 97838

Union Status: NonUnion

SIC:2037

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/26/1984

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 01/11/1985


Related Activity
Type Activity Nr Safety Health
Accident 360595367
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 7136001002 10/17/1984 11/15/1984 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14569487
Event: 09/14/1984
EXPOSED TO CHLORINE DIOXIDE GAS.

ON SEPTEMBER 14, 1984, BETWEEN 3 AND 3:30 PM, EMPLOYEES #1 THROUGH #8 INHALED CHLORINE DIOXIDE GAS (CL O2) WHILE WORKING IN THE FRENCH FRY PRODUCTION AREA AT THE LAMB-WESTON PLANT IN HERMISTON, OREGON. THE CHLORINE DIOXIDE IS SUSPENDED IN WATER TO HELP KEEP BACTERIA LEVELS LOW IN THE POTOTOES AS THEY FLOW THROUGH THE SYSTEM. A SERIES OF MECHANICAL BREAKDOWNS CONTRIBUTED TO A LACK OF POTATOES FLOWING THROUGH THE CHLORINE DIOXIDE SYSTEM. SINCE THERE WAS NO PRODUCT TO TIE UP OR DISSOLVE THE CHLORINE DIOXIDE, THE CONCENTRATION IN THE SYSTEM BECAME TOO HIGH, THEREBY CAUSING THE CHLORINE DIOXIDE TO "GAS OFF" INTO THE AMBIENT AIR. MOST OF THE EMPLOYEES WERE WORKING IN AND AROUND THE CHLORINE DIOXIDE AREA, CLEANING UP THE POTATOES OR OTHERWISE TRYING TO GET PRODUCTION BACK TO NORMAL. CHLORINE DIOXIDE IS HEAVIER THAN AIR SO IT REMAINED AT FLOOR LEVEL AND CONTINUED TO ACCUMULATE. THE CHLORINE DIOXIDE SYSTEM WAS EVENTUALLY SHUT DOWN AROUND 3:15 PM, AFTER THE EMPLOYEES COMPLAINED OF COUGHING, SORE THROATS AND HEADACHES. THEY COMPLETED THEIR SHIFT AND WENT TO THE HOSPITAL THE NEXT DAY. ALL BUT ONE WERE TREATED AND RELEASED.

Keywords: RESPIRATORY, THROAT, HEADACHE, INHALATION, CHLORINE DIOXIDE, COUGH

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 15099617 Hospitalized injury Asphyxia Inspectors, testers and graders
2 15099617 Hospitalized injury Asphyxia Miscellaneous plant and system operators
3 15099617 Hospitalized injury Asphyxia Supervisors; handlers,equip-cleaners,laborers nec
4 15099617 Hospitalized injury Asphyxia Supervisors; handlers,equip-cleaners,laborers nec
5 15099617 Hospitalized injury Asphyxia Miscellaneous plant and system operators
6 15099617 Hospitalized injury Asphyxia Inspectors, testers and graders
7 15099617 Hospitalized injury Asphyxia Supervisors; handlers,equip-cleaners,laborers nec
8 15099617 Hospitalized injury Asphyxia Supervisors; handlers,equip-cleaners,laborers nec
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close