Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Inspection Detail

Case Status: OPEN

Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.

Inspection: 1509756.015 - Ics Distribution, Llc

Inspection Information - Office: Houston North

 

Inspection Nr: 1509756.015
Report ID: 0626600
Date Opened: 01/12/2021

Site Address:
Ics Distribution, Llc
1314 West Sam Houston Parkway North
Houston, TX 77043

Mailing Address:
1314 West Sam Houston Parkway North, Houston, TX 77043

Union Status: NonUnion

SIC:

NAICS: 532490/Other Commercial and Industrial Machinery and Equipment Rental and Leasing


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/12/2021

Emphasis:

Case Closed:


Related Activity
Type Activity Nr Safety Health
Accident 1719232
Case Status: OPEN
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $9,557 $0 $0 $0 $0 $9,557
Current Penalty $9,557 $0 $0 $0 $0 $9,557
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A01 06/04/2021 06/10/2021 $9,557 $9,557 $0 06/17/2021 F - Formal Settlement  

Investigation Summary

Investigation Nr: 132336.015
Event: 01/12/2021
Employee Is Killed After Being Pulled Into Air Compressor

At 8:55 a.m. on January 12, 2021, an employee was observing pressure and functio n testing of an 5C2 air compressor being conducted by Coworker #1, Coworker #2 a nd Coworker #3. Coworker #1 locked out the 4160 volt energy source for the comp ressor. Once pretest and warm up tasks were completed, Coworker #1 removed his l ock and Coworker #1, Coworker #2 and Coworker #3 started up the compressor at t he control panel. The employee walked past the inlet and his body was pulled int o the compressor. Coworker #1 hit the emergency stop shutting down the compresso r, pulled the employee from the machine and began CPR. Coworker #2 and Coworker #3 called for help. Emergency Medical Services arrived and administered emergenc y care but the employee died at the scene.

Keywords:caught by, caught in, compressed air, compressor, electric switch, electronic control, emergency stop, energized, engine, lockout, lockout/tagout, machine guarding, machine operator, maintenance, unguarded

Investigated Inspection
# Inspection Age Sex Degree Nature Occupation
1 1509756.015 Fatality Fabricating machine operators, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.