Inspection Detail
Inspection: 1508099.015 - 147074 - Veolia Es Technical Solutions, L.L.C.
Inspection Information - Office: Nc Winston-Salem
Site Address:
147074 - Veolia Es Technical Solutions, L.L.C.
275 Aiken Road
Woodfin, NC 28804
Mailing Address:
53 State Street, Ste. 14, Boston, MA 02109
Union Status: NonUnion
SIC:4953
NAICS: 562211/Hazardous Waste Treatment and Disposal
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/23/2020
Emphasis:
Case Closed: 03/12/2021
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1710237 |
Investigation Summary
At 1:40 p.m. on December 22, 2020, an employee drove a forklift into a tractor t railer after loading the material onto the truck trailer for shipment. The truck started to pull away from the dock while the employee was riding the forklift. The employee fell off the forklift seat and struck to the concrete. The employee died because of fatal head injuries.
Keywords:concrete, fall, forklift, head, trailer, trailer truck
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 1508099.015 | Fatality | Occupation not reported |