Inspection Detail
Inspection: 1507359 - R & R Well & Pump Inc
Inspection Information - Office: Denver Area Office
Site Address:
R & R Well & Pump Inc
11098 Prospect Road
Lyrant, CO 81524
Mailing Address:
Po Box 577, Greely, CO 80632
Union Status: NonUnion
SIC:1781
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/25/1984
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 11/21/1984
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360555015 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 2 | 3 | |||
| Current Violations | 1 | 2 | 3 | |||
| Initial Penalty | $0 | $7,000 | $0 | $0 | $0 | $7,000 |
| Current Penalty | $0 | $3,500 | $0 | $0 | $0 | $3,500 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Willful | 19260550 A15 I | 08/02/1984 | 08/05/1984 | $3,500 | $7,000 | $0 | I - Informal Settlement | ||
| 2. | 02001 | Other | 19040008 | 08/02/1984 | 08/05/1984 | $0 | $0 | $0 | - | ||
| 3. | 02002 | Other | 19260550 A06 | 08/02/1984 | 09/03/1984 | $0 | $0 | $0 | - |
Investigation Summary
AN EMPLOYEE OF A WATER WELL CONTRACTOR WAS TO INSTALL A PUMP IN A HOLE FOR A WELL HOUSE. WHEN HE POSITIONED THE MAST OF THE DERRICK TRUCK OVER THE HOLE, THE DERRICK MADE CONTACT WITH AN OVERHEAD POWER LINE. CURRENT PASSED THROUGH THE DERRICK, THE OPERATING CONTROL, AND THE EMPLOYEE TO GROUND. THE EMPLOYEE WAS ELECTROCUTED.
Keywords: DERRICK TRUCK, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, WELL, E C
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1507359 | Fatality | Electric Shock | Construction trades, n.e.c. |