Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1506697.015 - Powercon Corporation

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 1506697.015
Report ID: 0352450
Date Opened: 12/16/2020

Site Address:
Powercon Corporation
1731 Midway Road
Odenton, MD 21113

Mailing Address:
1551 Florida Avenue, Severn, MD 21144

Union Status: NonUnion

SIC:

NAICS: 335313/Switchgear and Switchboard Apparatus Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/22/2021

Emphasis: N:Amputate

Case Closed: 05/10/2021


Related Activity
Type Activity Nr Safety Health
Accident 1706519
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $4,350 $0 $0 $0 $0 $4,350
Current Penalty $2,740 $0 $0 $0 $0 $2,740
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100147 C04 I 03/18/2021 04/20/2021 $2,740 $4,350 $0 I - Informal Settlement  
2. 01001B Serious 19100147 C05 I 03/18/2021 03/26/2021 $0 $0 $0 I - Informal Settlement  
3. 01001C Serious 19100147 C06 I 03/18/2021 04/20/2021 $0 $0 $0 I - Informal Settlement  
4. 01001D Serious 19100147 C07 I 03/18/2021 04/20/2021 $0 $0 $0 I - Informal Settlement  
5. 02001 Other 19100147 C06 II 03/18/2021 04/20/2021 $0 $0 $0 I - Informal Settlement  
6. 02002 Other 19100147 C07 IV 03/18/2021 04/20/2021 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 133559.015
Event: 12/15/2020
Employee suffers partial amputation of left thumb while work

At 6:00 a.m. on December 15, 2020, Employee #1 was working with a coworker to disassemble and assemble the nozzles and molds in a Hubers Clamping Machine Model #2791 for cleaning. While adjusting an epoxy injection nozzle located 26-1/2 inches from the floor, the coworker left the machine to the control panel to actuate the nozzle. Despite informing Employee #1 to stand clear, the coworker did not have visibility of him due to the panel's location. When the coworker started the machine, Employee #1 yelled out as his left thumb was caught by the pneumatically driven nozzle, which was operating at a pressure of approximately 80 psi. Paramedics were called, and Employee #1 was transported to the hospital for treatment, resulting in a partial amputation of the left thumb. The employee was not hospitalized.

Keywords: Amputation, Hospital, Thumb

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1506697.015 67 M Non Hospitalized injury Machinists
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close