Inspection Detail
Note: The following inspection has not been indicated as closed. Please be aware that the information shown may change, e.g. violations may be added or deleted. For open cases, in which a citation has been issued, the citation information may not be available for 5 days following receipt by the employer for Federal inspections or for 30 days following receipt by the employer for State inspections.
Inspection: 1505237.015 - Sm Roofing And Siding
Inspection Information - Office: Marlton
Site Address:
Sm Roofing And Siding
207 20th Street S
Bridgeton, NJ 08302
Mailing Address:
449 Bridgeport Ave, Oceanport, NJ 07757
Union Status: NonUnion
SIC:
NAICS: 238160/Roofing Contractors
Inspection Type: Fat/Cat
Scope: Complete
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/08/2020
Emphasis: L:Fall
Case Closed:
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1700182 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 7 | 7 | ||||
Current Violations | 7 | 7 | ||||
Initial Penalty | $28,672 | $0 | $0 | $0 | $0 | $28,672 |
Current Penalty | $28,672 | $0 | $0 | $0 | $0 | $28,672 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260451 F06 | 06/03/2021 | 06/09/2021 | $4,096 | $4,096 | $0 | Z - Issued | ||
2. | 01002 | Serious | 19260451 F07 | 06/03/2021 | 06/09/2021 | $4,096 | $4,096 | $0 | Z - Issued | ||
3. | 01003 | Serious | 19260451 G01 VII | 06/03/2021 | 06/09/2021 | $4,096 | $4,096 | $0 | Z - Issued | ||
4. | 01004 | Serious | 19260452 J02 | 06/03/2021 | 06/09/2021 | $4,096 | $4,096 | $0 | Z - Issued | ||
5. | 01005 | Serious | 19260454 A02 | 06/03/2021 | 06/09/2021 | $4,096 | $4,096 | $0 | Z - Issued | ||
6. | 01006 | Serious | 19260501 B13 | 06/03/2021 | 06/09/2021 | $4,096 | $4,096 | $0 | Z - Issued | ||
7. | 01007 | Serious | 19260503 A01 | 06/03/2021 | 06/09/2021 | $4,096 | $4,096 | $0 | Z - Issued |
Investigation Summary
At 5:45 p.m. on December 6, 2020, Employees #1 and #2 and coworkers, employed by a roofing and siding company, were working at the construction site of a new two-story residence. Employees #1 and #2 were repositioning a pump jack scaffold from the back of the house to another location. According to a coworker who witnessed the event, the two employees were in the process of laying down parallel to the house a 36-foot Alum-A-Pole, part of the scaffold system, when they appeared to lose control of the pole as a gust of wind came around the house's corner. The pole toppled onto energized overhead power lines 8 to 10 feet away, and electrical current flowed through the pole to the employees. Employee #1 was electrocuted. Employee #2 was transported to the hospital for treatment of electric shock injuries.
Keywords:contact, electric shock, electrocuted, energized, falling object, lost control, metal pole, overhead power line, pump jack scaffold, residential construction, struck against, unstable position, windy
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 1505237.015 | Hospitalized injury | ||||
2 | 1505237.015 | Fatality | Construction trades, n.e.c. |