Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1503542.015 - Servicon Systems, Inc.

Inspection Information - Office: Van Nuys District Office

 

Inspection Nr: 1503542.015
Report ID: 0950643
Date Opened: 11/16/2020

Site Address:
Servicon Systems, Inc.
21860 Burbank Blvd.
Woodland Hills, CA 91367

Mailing Address:
3965 Landmark Street, Culver City, CA 90232

Union Status: NonUnion

SIC:

NAICS: 561320/Temporary Help Services


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 09/29/2021

Emphasis:

Case Closed: 09/29/2021


Related Activity
Type Activity Nr Safety Health
Accident 1689841
Inspection 1503531 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 143709.015
Event: 11/13/2020
Employee is killed after being found unconscious

At 02:00 p.m. on November 13, 2020, an employee was on break. The employee was found unconscious in the break/maintenance room. Pending the coroner's report, the cause of death was unconsciousness.

Keywords: Unconsciousness

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1503542.015 37 M Fatality
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close