Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1502748.015 - Durez Corporation

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 1502748.015
Report ID: 0524700
Date Opened: 11/17/2020

Site Address:
Durez Corporation
13717 Us Hwy. 68 S
Kenton, OH 43326

Mailing Address:
13717 Us Hwy. 68 S, Kenton, OH 43326

Union Status: Union

SIC:

NAICS: 325211/Plastics Material and Resin Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/17/2020

Emphasis: N:Amputate

Case Closed: 04/08/2021


Related Activity
Type Activity Nr Safety Health
Referral 1685883 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 1 4
Current Violations 2 1 3
Initial Penalty $40,548 $0 $0 $0 $0 $40,548
Current Penalty $20,274 $0 $0 $0 $0 $20,274
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100147 C04 I 01/19/2021 02/17/2021 $10,137 $13,516 $0 I - Informal Settlement  
2. 01001B Serious 19100147 D 01/19/2021 03/03/2021 $0 $13,516 $0 I - Informal Settlement  
3. 01002 Serious 19100147 C07 I 01/19/2021 03/03/2021 $10,137 $13,516 $0 I - Informal Settlement  
4. 02001 Other 19100132 D02 01/19/2021 03/03/2021 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 131145.015
Event: 11/11/2020
Employee partially amputates finger while removing clogged d

At 1:15 a.m. on November 11, 2020, an employee was operating a grinder. The grinder turned off due to a clogged dust collector. The employee was instructed by a coworker to remove the inspection port/plate located at the bottom of the dust collector hopper in attempt to clear the jam. The equipment was not shut off and locked out. Unaware of an operating rotary valve feeder located at the bottom of the hopper, the employee reached into the hopper to clear dust and contacted a rotary valve feeder with his finger. The employee sustained a partial amputation to his right index ring finger. The employee was treated without hospitalization.

Keywords: Amputated, Amputation, Bypass Guard, Clogged, Contact, Dust Collector, Finger, Grinder, Jammed, Lockout/Tagout, Machine operator, Partial Amputation, Reaching, Reaching In, Rotating Parts

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1502748.015 35 M Non Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.