Inspection Detail
Inspection: 1502398.015 - University Of Dayton Research Institute
Inspection Information - Office: Jacksonville Area Office
Site Address:
University Of Dayton Research Institute
2306 Perimeter Rd
Eglin Afb, FL 32542
Mailing Address:
300 College Park, Dayton, OH 45469
Union Status: NonUnion
SIC:
NAICS: 541712
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/17/2020
Emphasis:
Case Closed: 05/10/2021
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1683641 | Yes | |
| Inspection | 1503530 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | ||||||
| Initial Penalty | $13,653 | $0 | $0 | $0 | $0 | $13,653 |
| Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19101450 F04 I B | 02/19/2021 | 03/17/2021 | $0 | $13,653 | $0 | I - Informal Settlement | Citation has been deleted. |
Investigation Summary
At 12:30 p.m. on November 5, 2020, an employee removed a ceramic jar containing a chemical (ammonium periodate) from a vacuum oven. The chemical inside the ceramic jar exploded while resting on the lab table. The employee sustained multiple lacerations and the amputation of the right hand. The employee was hospitalized.
Keywords: Amputated, Amputation, Chemical, Exploded, Explosion, Hand, Laceration, Oven
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1502398.015 | 24 | F | Hospitalized injury | Chemists, except biochemists |