Inspection Detail
Inspection: 1499586.015 - Tractor Supply Company
Inspection Information - Office: Redding District Office
Site Address:
Tractor Supply Company
1455 S. Main Street
Yreka, CA 96097
Mailing Address:
1455 S. Main Street, Yreka, CA 96097
Union Status: NonUnion
SIC:
NAICS: 444220/ Nursery, Garden Center, and Farm Supply Stores
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/28/2020
Emphasis:
Case Closed: 02/10/2023
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1673195 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $12,375 | $0 | $0 | $0 | $0 | $12,375 |
Current Penalty | $6,750 | $0 | $0 | $0 | $0 | $6,750 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 5592(E) | 12/28/2020 | $0 | $5,625 | $0 | 01/13/2021 | O - Administrative Law Judge Order | Citation has been deleted. | |
2. | 02001 | Serious | 5603 | 12/28/2020 | $6,750 | $6,750 | $0 | 01/13/2021 | O - Administrative Law Judge Order |
Investigation Summary
At 10:20 a.m. on October 12, 2020, an employee working as a cashier for a farm supply store was filling propane tanks at the propane dispensing station. After filling each tank, the employee would shut down the nozzle to prevent propane from pumping over the customer tank. The employee would then release the pressure valve on the tank and discharge the line of the propane nozzle. The employee was performing this propane tank-filling task and had just released pressure after filling up a customer tank. After the employee finished filling the tank and discharging the propane line, a loud ignition sound came from the direction of the cabinet. The employee was struck by fire and burned. The employee sustained second- and third-degree burns to her hands, arms and face and was hospitalized.
Keywords: Arm, Burn, Cashier, Chemical Vapor, Face, Filling, Filling Station, Fire, Flammable Vapors, Hand, High Pressure, Ignite, Ignition, Inhalation, Lack of Engineering Controls, Pressure, Propane, Regulator Valve, Skin, Tank, Valve, Vapor
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1499586.015 | 21 | F | Hospitalized injury | Cashiers |