Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1499586.015 - Tractor Supply Company

Inspection Information - Office: Redding District Office

 

Inspection Nr: 1499586.015
Report ID: 0950623
Date Opened: 10/26/2020

Site Address:
Tractor Supply Company
1455 S. Main Street
Yreka, CA 96097

Mailing Address:
1455 S. Main Street, Yreka, CA 96097

Union Status: NonUnion

SIC:

NAICS: 444220/ Nursery, Garden Center, and Farm Supply Stores


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/28/2020

Emphasis:

Case Closed: 02/10/2023


Related Activity
Type Activity Nr Safety Health
Accident 1673195
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $12,375 $0 $0 $0 $0 $12,375
Current Penalty $6,750 $0 $0 $0 $0 $6,750
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5592(E) 12/28/2020 $0 $5,625 $0 01/13/2021 O - Administrative Law Judge Order Citation has been deleted.
2. 02001 Serious 5603 12/28/2020 $6,750 $6,750 $0 01/13/2021 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 131921.015
Event: 10/12/2020
Employee burns face and arms from ignition of propane vapors

At 10:20 a.m. on October 12, 2020, an employee working as a cashier for a farm supply store was filling propane tanks at the propane dispensing station. After filling each tank, the employee would shut down the nozzle to prevent propane from pumping over the customer tank. The employee would then release the pressure valve on the tank and discharge the line of the propane nozzle. The employee was performing this propane tank-filling task and had just released pressure after filling up a customer tank. After the employee finished filling the tank and discharging the propane line, a loud ignition sound came from the direction of the cabinet. The employee was struck by fire and burned. The employee sustained second- and third-degree burns to her hands, arms and face and was hospitalized.

Keywords: Arm, Burn, Cashier, Chemical Vapor, Face, Filling, Filling Station, Fire, Flammable Vapors, Hand, High Pressure, Ignite, Ignition, Inhalation, Lack of Engineering Controls, Pressure, Propane, Regulator Valve, Skin, Tank, Valve, Vapor

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1499586.015 21 F Hospitalized injury Cashiers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.