Case Status: CLOSED

Inspection: 1497735.015 - Precision Strip, Inc.

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 1497735.015
Report ID: 0524700
Date Opened: 10/15/2020

Site Address:
Precision Strip, Inc.
86 S. Ohio Street
Minster, OH 45865

Mailing Address:
86 S. Ohio Street, Minster, OH 45865

Union Status: NonUnion

SIC:

NAICS: 331221/Rolled Steel Shape Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/15/2020

Emphasis: N:Amputate

Case Closed: 02/05/2021


Related Activity
Type Activity Nr Safety Health
Referral 1671497 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $13,494 $0 $0 $0 $0 $13,494
Current Penalty $6,747 $0 $0 $0 $0 $6,747
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A01 12/08/2020 01/04/2021 $6,747 $13,494 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 130398.015
Event: 10/12/2020
Employee partially amputates finger on truing device

At 11:15 a.m. on October 23, 2020, an employee working as a machine operator for a rolled steel manufacturer was setting up a Diamond Truing Device. The employee was manually adjusting the truing diamond in order to clean a grinding wheel on a Cincinnati OD Knife Machine. The employee moved the device horizontally until it touched the rotating grinding wheel. The manual adjustment knob for truing diamond is located within 4 inches of the grinding wheel. The grinder operates at 2767 revolutions per minute (RPM). While performing this task, the truing device rotated to the vertical position and crushed the employee's right middle finger between the lever used to alight the grinding wheel and the guard to the grinding wheel. The employee partially amputated his finger between first and second knuckle and was hospitalized.

Keywords: Adjust, Amputated, Amputation, Caught Between, Finger, Grinder, Grinding, Grinding Wheel, Instantaneous amputation, Knife, Knuckle, Lack of Engineering Controls, Machine Guarding, Machine operator, Partial Amputation, Rotating Knife, Rotating Parts, Steel, Traumatic Amputation

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1497735.015 45 M Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.