Powered by GoogleTranslate

Inspection Detail

Inspection: 14968564 - Electrical Corp Of America

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 14968564
Report ID: 0453710
Date Opened: 06/06/1985

Site Address:
Electrical Corp Of America
7855 King Tobaccoville Rd
King, NC 27021

Mailing Address:
P O Box 1095, King, NC 27021

Union Status: Union

SIC:1731

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 06/06/1985

Emphasis:

Case Closed: 12/31/1988


Related Activity
Type Activity Nr Safety Health
Accident 360611867
Complaint 70803853 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $640 $0 $0 $0 $0 $640
Current Penalty $640 $0 $0 $0 $0 $640
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260055 A 06/24/1985 06/27/1985 $640 $640 $0 11/22/1985 J - ALJ Decision  
2. 01001B Serious 19260055 B 06/24/1985 06/27/1985 $0 $0 $0 11/22/1985 J - ALJ Decision  

Investigation Summary

Investigation Nr: 14339741
Event: 05/03/1985
EMPLOYEES EXPOSED TO CARBON MONOXIDE IN BASEMENT

ON MAY 3, 1985, FIVE EMPLOYEES REPORTED TO THE NURSE AND COMPLAINED OF HEADACHES, NAUSEA AND GENERAL MALAISE. ONE EMPLOYEE HAD CHERRY RED LIPS. FOUR OF THE EMPLOYEES WERE SENT TO THE HOSPITAL. THE NEXT DAY, TWENTY FOUR EMPLOYEES REPORTED TO THE NURSE'S STATION WITH SIMILAR SYMPTOMS. THESE WORKERS WERE ENGAGED IN ELECTRICAL WORK IN THE BASEMENT OF A MANUFACTURING AREA. CONSTRUCTION WORK WAS UNDERWAY IN THE MANUFACTURING AREA. TWO OF THE TWENTY FOUR WERE TAKEN TO THE HOSPITAL THE SECOND DAY. THE EMPLOYEES WERE APPARENTLY EXPOSED TO HIGH LEVELS OF CARBON MONOXIDE.

Keywords: VENTILATION, HEADACHE, INHALATION, NAUSEA, TOXIC FUMES, CARBON MONOXIDE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 14968564 Non Hospitalized injury Asphyxia Electricians
2 14968564 Non Hospitalized injury Asphyxia Electricians
3 14968564 Non Hospitalized injury Asphyxia Electricians
4 14968564 Non Hospitalized injury Asphyxia Electricians
5 14968564 Non Hospitalized injury Asphyxia Electricians
6 14968564 Non Hospitalized injury Asphyxia Electricians
7 14968564 Non Hospitalized injury Asphyxia Electricians
8 14968564 Hospitalized injury Asphyxia Electricians
9 14968564 Non Hospitalized injury Asphyxia Electricians
10 14968564 Non Hospitalized injury Asphyxia Electricians
11 14968564 Non Hospitalized injury Asphyxia Electricians
12 14968564 Non Hospitalized injury Asphyxia Electricians
13 14968564 Non Hospitalized injury Asphyxia Electricians
14 14968564 Non Hospitalized injury Asphyxia Electricians
15 14968564 Non Hospitalized injury Asphyxia Electricians
16 14968564 Non Hospitalized injury Asphyxia Electricians
17 14968564 Non Hospitalized injury Asphyxia Electricians
18 14968564 Non Hospitalized injury Asphyxia Electricians
19 14968564 Non Hospitalized injury Asphyxia Electricians
20 14968564 Non Hospitalized injury Asphyxia Electricians
21 14968564 Non Hospitalized injury Asphyxia Electricians
22 14968564 Non Hospitalized injury Asphyxia Electricians
23 14968564 Non Hospitalized injury Asphyxia Electricians
24 14968564 Hospitalized injury Asphyxia Electricians
25 14968564 Hospitalized injury Asphyxia Electricians
26 14968564 Hospitalized injury Asphyxia Electricians
27 14968564 Hospitalized injury Asphyxia Electricians
28 14968564 Hospitalized injury Asphyxia Electricians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close