Powered by GoogleTranslate

Inspection Detail

Inspection: 14963987 - Yeargin Western Constructors Inc

Inspection Information - Office: State Of New Mexico Environment Department Occupational Health & Safety Bureau

 

Inspection Nr: 14963987
Report ID: 0653510
Date Opened: 10/22/1984

Site Address:
Yeargin Western Constructors Inc
Pan American Hyway Ne
Albuquerque, NM 87110

Mailing Address:
Po Box 8510, Albuquerque, NM 87198

Union Status: NonUnion

SIC:1611

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 10/22/1984

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 10/22/1984


Related Activity
Type Activity Nr Safety Health
Accident 36593325

Investigation Summary

Investigation Nr: 14557466
Event: 10/19/1984
Employee killed when run over by backing grader

Employee #1 was assisting at a road grading operation. The Caterpillar 1406 grader was in third gear at approximately half throttle and moving backward in preparation to make another pass. After it started to reverse, Employee #1 moved into its path and either tripped or was struck by the ripper. He fell beneath the grader's wheels and was killed. At the time of the accident, the back-up alarm was sounding. It is not known why Employee #1 moved behind the grader.

Keywords: GRADER, WORK RULES, CONSTRUCTION, EARTHMOVING EQUIP, CRUSHED, RUN OVER, BACKING UP

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 14963987 Fatality Other Truck drivers, heavy
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.