Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1495152.015 - Nikkiso Cryo, Inc.

Inspection Information - Office: Nv-E-Las Vegas 0953220

 

Inspection Nr: 1495152.015
Report ID: 0953220
Date Opened: 09/28/2020

Site Address:
Nikkiso Cryo, Inc.
4661 Eaker Street
North Las Vegas, NV 89081

Mailing Address:
4661 Eaker Street, North Las Vegas, NV 89081

Union Status: NonUnion

SIC:

NAICS: 333911/Pump and Pumping Equipment Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/28/2021

Emphasis:

Case Closed: 03/17/2021


Related Activity
Type Activity Nr Safety Health
Referral 1667184 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $0 $109,301 $0 $0 $0 $109,301
Current Penalty $0 $65,581 $0 $0 $0 $65,581
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Willful 19100028 B01 I 01/29/2021 $65,581 $109,301 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 129941.015
Event: 09/25/2020
Employee fractures ribs, shoulder, and hip in fall from elev

At 11:45 a.m. on September 25, 2020, an employee was removing bolts from the top plate of a specialty pump that was being torn down for inspection at the west end of the vertical pump assembly stand. The employee was using a pneumatic impact wrench to remove the bolts, while standing on the platform of the vertical pump assembly stand that held the specialty pump in place. The employee was maneuvering around the vertical pump assembly stand's platform to access the bolts of the top plate of the pump. The employee was approximately three feet from a section of the guardrail that was removed and left off during the installation of the specialty pump onto the vertical pump assembly stand. The employee took a step off the stand's platform while attempting to remove the bolts at the north side of the specialty pump's top plate. The employee fell approximately 20 feet. The employee landed on the concrete slab directly below the vertical pump assembly stand. The employee was hospitalized to treat fractures to the right shoulder, right ribs, and right hip.

Keywords: Bolt, Concrete Slab, Fall, Fall From Elevation, Fracture, Guardrail, Hip, Pneumatic, Pneumatic equipment, Pump, Removing, Rib, Shoulder, Unguarded, Wrench

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1495152.015 18 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close