Inspection Detail
Inspection: 1495034.015 - Fermin Construction Llc
Inspection Information - Office: Austin Area Office
Site Address:
Fermin Construction Llc
6081 Fm 1660
Hutto, TX 78634
Mailing Address:
178 Monterrey Hills Dr,, Del Valle, TX 78617
Union Status: NonUnion
SIC:
NAICS: 238110/Poured Concrete Foundation and Structure Contractors
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/01/2020
Emphasis: L:Constr6
Case Closed: 02/01/2021
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1666545 | Yes | |
| Inspection | 1495030 | Yes | |
| Inspection | 1495032 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $1,735 | $0 | $0 | $0 | $0 | $1,735 |
| Current Penalty | $1,041 | $0 | $0 | $0 | $0 | $1,041 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260021 B02 | 12/22/2020 | 12/29/2020 | $1,041 | $1,735 | $0 | I - Informal Settlement |
Investigation Summary
At 3:30 p.m. on September 29, 2020, a pumper truck came in contact with overhead power lines. Electricity arced to an employee, who suffered electrical burns. The employee was hospitalized for treatment.
Keywords: Electric Arc Flash, Electric Shock, Electrical, Electrical Burn, Overhead Power Line, Truck
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1495034.015 | 26 | M | Hospitalized injury | Construction laborers |