Inspection Detail
Inspection: 1493954.015 - Glovis America, Inc
Inspection Information - Office: Mobile Area Office
Site Address:
Glovis America, Inc
250 Hyundai Blvd
Montgomery, AL 36105
Mailing Address:
250 Hyundai Blvd, Montgomery, AL 36105
Union Status: NonUnion
SIC:
NAICS: 541614/ Process, Physical Distribution, and Logistics Consulting Services
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/22/2020
Emphasis: L:Autosup
Case Closed: 01/22/2021
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1658296 | Yes |
Investigation Summary
At 7:00 a.m. on August 29, 2020, a crew was in the process of disconnecting the locomotive from the rail cars. An employee crossed over the tracks by climbing over the knuckle, while the rail cars where still attached, and the entire system had not come to a complete stop. The train cars moved, pinning the employee. The employee suffered an amputation of all the toes on the right foot and was hospitalized.
Keywords: Amputated, Amputation, Climbing, Disconnecting, Flatbed Rail Car, Foot, Knuckle, Locomotive, Moving, Moving Object, Pinned, Toe
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1493954.015 | 24 | M | Hospitalized injury | Railroad brake, signal and switch operators |