Inspection Detail
Inspection: 1490951.015 - H&H Corporate Llc
Inspection Information - Office: Englewood Area Office
Site Address:
H&H Corporate Llc
5655 N Peterson Rd
Sedalia, CO 80135
Mailing Address:
5655 N Peterson Rd, Sedalia, CO 80135
Union Status: NonUnion
SIC:
NAICS: 325411/Medicinal and Botanical Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 09/02/2020
Emphasis:
Case Closed: 01/14/2021
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1652150 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
Current Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100106 E02 IV C | 10/09/2020 | 11/30/2020 | $0 | $0 | $0 | Z - Issued | ||
2. | 01002 | Serious | 19100106 E06 I | 10/09/2020 | 11/30/2020 | $0 | $0 | $0 | Z - Issued |
Investigation Summary
At 2:30 p.m. on August 27, 2020, an employee was testing a new membrane filter machine with fresh heptane solvent. The heptane solvent leaked from a valve, and the employee caught it with a plastic pan and poured it into a bucket. Vapor from the heptane solvent ignited due to a nearby heat gun the employee had left turned on. The employee suffered burns to the hand, forearm and neck. The employee was hospitalized.
Keywords: Burn, Chemical Vapor, Flammable Vapors, Forearm, Hand, Heptane, Ignite, Leak, Neck, Testing, Valve, Vapor
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1490951.015 | 30 | M | Hospitalized injury | Chemical technicians |