Powered by GoogleTranslate

Inspection Detail

Inspection: 14903942 - Harvey J Lorentz Roofing

Inspection Information - Office: Minnesota Department Of Labor And Industry

 

Inspection Nr: 14903942
Report ID: 0552700
Date Opened: 10/12/1984

Site Address:
Harvey J Lorentz Roofing
Orvis Juliar Farm 3 Miles West Of
St Clair, MN 56080

Mailing Address:
339 Mckinley, No Mankato, MN 56001

Union Status: NonUnion

SIC:1761

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/12/1984

Emphasis:

Case Closed: 11/01/1984


Related Activity
Type Activity Nr Safety Health
Accident 360588958

Investigation Summary

Investigation Nr: 14447940
Event: 10/11/1984
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LADDER

THREE EMPLOYEES WERE RAISING A SHINGLE LADDER HOIST. ONE OF THEM HELD THE BASE OF THE HOIST WITH HIS FEET AND HANDS, AS THE OTHER TWO EMPLOYEES LIFTED THE OPPOSITE END HAND OVER HAND. ON THE WAY UP, THE ALUMINUM LADDER CONTACTED A 68-KILOVOLT OVERHEAD POWER LINE. THE EMPLOYEE HOLDING THE BASE DIED AT THE HOSPITAL. THE OTHER EMPLOYEES RECEIVED 3RD AND 4TH DEGREE BURNS TO THEIR HANDS AND FEET.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, LADDER, HOIST, E C, METAL LADDER, ELECTRIC SHOCK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 14903942 Hospitalized injury Electric Shock Roofers
2 14903942 Fatality Electric Shock Supervisors, n.e.c.
3 14903942 Hospitalized injury Electric Shock Roofers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.