Inspection: 1489052.015 - H & H Utility Excavating, Inc.

Inspection Information - Office: Appleton Area Office

 

Inspection Nr: 1489052.015
Report ID: 0521100
Date Opened: 08/20/2020

Site Address:
H & H Utility Excavating, Inc.
2860 Lake Forest Park Road
Sturgeon Bay, WI 54235

Mailing Address:
W4038 Hoffmann Road, Plymouth, WI 53073

Union Status: Union

SIC:

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/20/2020

Emphasis:

Case Closed: 10/22/2020


Related Activity
Type Activity Nr Safety Health
Referral 1646235 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $7,423 $0 $0 $0 $0 $7,423
Current Penalty $3,712 $0 $0 $0 $0 $3,712
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260152 G10 09/23/2020 10/22/2020 $3,712 $7,423 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 128806.015
Event: 08/18/2020
Employee receives burns while removing running equipment fue

At 5:00 p.m. on August 18, 2020, Employee #1 was working for a water and sewer line contractor. Employee #1 was operating a Vermeer ST750A Mixing System which mixes and provides boring gel for the horizontal boring process. Employee #1 removed the fuel cap for the Vermeer ST750A Mixing System to verify there was enough fuel to complete the workday while it was running. Gasoline spurted out of the fuel tank and ignited, causing burns to the upper body of Employee #1. Employee #1 was hospitalized to treat burns to the face, head, neck, arms, and upper torso.

Keywords: Arm, Burn, Drill, Drilling, Drilling Mud, Face, Fire, Flammable Liquid, Flammable Vapors, Gasoline, Head, Neck, Torso

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1489052.015 37 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.