Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1488335.015 - Penn Stainless Products, Inc.

Inspection Information - Office: Erie Area Office

 

Inspection Nr: 1488335.015
Report ID: 0336000
Date Opened: 08/13/2020

Site Address:
Penn Stainless Products, Inc.
102 Mcquiston Drive
Jackson Center, PA 16133

Mailing Address:
102 Mcquiston Drive, Jackson Center, PA 16133

Union Status: NonUnion

SIC:

NAICS: 332710/Machine Shops


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/13/2020

Emphasis:

Case Closed: 01/11/2021


Related Activity
Type Activity Nr Safety Health
Referral 1641047 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $10,618 $0 $0 $0 $0 $10,618
Current Penalty $5,500 $0 $0 $0 $0 $5,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100145 F03 12/10/2020 01/07/2021 $2,000 $6,636 $0 I - Informal Settlement  
2. 01002A Serious 19100334 A02 II 12/10/2020 $3,500 $3,982 $0 I - Informal Settlement  
3. 01002B Serious 19100305 G01 IV 12/10/2020 $0 $0 $0 I - Informal Settlement  
4. 01002C Serious 19100022 D01 12/10/2020 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 128677.015
Event: 08/04/2020
Employee incurs amputation after steel plate falls on finger

At 2:00 p.m. on August 4, 2020, an employee was operating a Koike Aronson Mastergraph EX2 plasma cutter had just released a cam assembly on a Renfroe JPA clamp and began to pull the clamp from a 3/8-inch by 60-inch by 240-inch 1600 pound 304 grade stainless steel plate that was still suspended about 1-inch above the table. The employee stated that when he reached to unhook the dog (cam assembly) the plate slid out of the clamp and fell approximately 1 inch from its suspended position to the table below where he was resting his hand. The employee's left middle finger was pinched between the plate and one of the slats on the plasma table. The employee incurred a traumatic left middle fingertip fracture requiring medical treatment (surgical amputation) but was not hospitalized.

Keywords: Amputated, Amputation, Attachment Hook, Carbon Steel Plate, Caught Between, Crushed, Crushing, Cutting, Falling Object, Finger, Fingertip, Hand, Machine operator, Partial Amputation, Pinched, Plasma, Steel, Steel Plate, Suspended Load, Unstable Load, Unstable Position

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1488335.015 48 M Non Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.