Powered by GoogleTranslate

Inspection Detail

Inspection: 14857239 - Mclean Contracting Company

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 14857239
Report ID: 0352410
Date Opened: 01/31/1985

Site Address:
Mclean Contracting Company
Rte. 213
Georgetown, MD 21930

Mailing Address:
1301 Fidelity Bldg., Baltimore, MD 21201

Union Status: NonUnion

SIC:1623

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/08/1985

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 06/17/1986


Related Activity
Type Activity Nr Safety Health
Accident 360586499
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $380 $0 $0 $0 $0 $380
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260550 B02 03/05/1985 03/08/1985 $380 $380 $0 03/28/1985 J - ALJ Decision Citation has been deleted.

Investigation Summary

Investigation Nr: 14197917
Event: 01/14/1985
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU LOAD LINE

A carpenter supervisor and three carpenters were helping a crane operator move a crane from one position to another. The five employees were near the crane, standing on the ground, placing blocking material under the left front outrigger and under the tandem front wheels. One of the carpenters was operating the control levers of the hydraulic outrigger. The controls were on the left side of the 63-metric-ton truck crane (Serial No. 3550-21) with a 34-meter-long boom. The crane operator had left the crane cab with the motor still running. He had not engaged the main hoist brake. The hook on the load line was suspended 14 meters above a 149.4-kilovolt overhead power line. The load line with its hook and block assembly descended from its position at the top of the boom and contacted the power line. The carpenter who was placing the material under the wheels received an electric shock and sustained burns to both feet and to his right hand. He was hospitalized for his injuries. The employees were trained by the employer's safety director, the job superintendent, and the supervisor. The employer had instituted weekly safety checklists and had presented each employee with a handbook that includes safety rules. The injured employee was wearing rubber boots and a hardhat.

Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, E GI IA, ELECTRIC SHOCK, LOAD LINE, CRANE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 14857239 Hospitalized injury Electric Shock Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.