Inspection: 14842421 - Chessie System Railroads

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 14842421
Report ID: 0352420
Date Opened: 04/02/1984

Site Address:
Chessie System Railroads
2 North Charles Street
Baltimore, MD 21201

Mailing Address:
801 Madison Avenue, Huntington West, VA 25704

Union Status: Union

SIC:4011

NAICS: 0 


Inspection Type: Complaint

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/01/1984

Emphasis:

Case Closed: 07/18/1984


Related Activity
Type Activity Nr Safety Health
Complaint 70724042 Yes
Complaint 70724158 Yes
Referral 900575333 Yes
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100036 D02 05/23/1984 05/26/1984 $0 $0 $0 -  
2. 01002 Other 19100037 K02 05/23/1984 05/26/1984 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 14460554
Event: 03/02/1984
FIRE (DESCRIPTION INCOMPLETE)

EMPLOYEES WORKING ON THE 13TH FLOOR ON 3-2-84 IN THE DATA ENTRY ROOM WERE NOT INFORMED OF THE FIRE IN THE BUILDING (40 EMPLOYEES EXPOSED) A INOPERABLE FIRE ALARM SYSTEM, INADEQUATE STAIRWELL LIGHTING AND NO BACKUP LIGHTING SYSTEM WAS ENCOUNTERED BY EMPLOYEES IN THIS BUILDING. EMPLOYEES ENCOUNTERED OBSTRUCTIONS IN STAIRWELL AND ON STEPS WHICH CONSISTED OF CONSTRUCTION RENOVATION DEBRIS SUCH AS DIRT, DUST, PIECES OF WOOD, SHEET ROCKCLUTTERED ALL OVER WITH A 3" BY 4" PIECE OF PLYWOOD OR SHEETROCK WAS HUNG ACROSSONE OF THE LANDINGS BLOCKING 80% OF THE EMPLOYEES EXIT PATH A 3' LONG 2" BY 4" MATERIAL HAD BEEN JUTTED OUT INTO THE WALKWAY. NUMEROUS OPENINGS OF VARIOUS SIZES COULD HAVE DETOURED THE EMPLOYEES EXIT AT ANY NUMBER OF POINTS WHEN THEY WERE GETTING OUT OF THIS BUILDING DURING THE FIRE. (THIS ABSTRACT NOT REVIEWED-NOT CLEAR WHAT HAPPENED. WG)

Keywords: FIRE

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 14842421 Occupation Not Listed
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.