Inspection Detail
Inspection: 1483341.015 - Delaval Manufacturing
Inspection Information - Office: Kansas City Area Office
Site Address:
Delaval Manufacturing
501 S. Mitchell Ave.
Chillicothe, MO 64601
Mailing Address:
501 S. Mitchell Ave., Chillicothe, MO 64601
Union Status: NonUnion
SIC:
NAICS: 339991/ Gasket, Packing, and Sealing Device Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 07/15/2020
Emphasis: L:Repvehicle
Case Closed: 10/27/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1621981 | Yes |
Investigation Summary
At 1:00 a.m. on July 8, 2020, an employee had installed a fan in production because he felt chilled. The employee was subsequently hospitalized with heat stroke.
Keywords: Dehydration, Fan, Heat, Heat Exhaustion, Heat index, Heat-related illness , High Temperature, Illness, Injury Illness Prevention Program, Maintenance, Medical Condition, Overheated, PPE, Training, Weather
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1483341.015 | 35 | M | Hospitalized injury | Machinery maintenance occupations |