Powered by GoogleTranslate

Inspection Detail

Inspection: 14820047 - Better Engineering Mfg

Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health

 

Inspection Nr: 14820047
Report ID: 0352420
Date Opened: 07/24/1984

Site Address:
Better Engineering Mfg
7101 Belair Road
Baltimore, MD 21206

Mailing Address:
, , 00000

Union Status: NonUnion

SIC:7539

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/06/1984

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 03/11/1985


Related Activity
Type Activity Nr Safety Health
Accident 360586036
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $0 $0 $0 $0 $0 $0
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19100252 B04 IXC 10/19/1984 10/22/1984 $0 $0 $0 11/05/1984 R - Review Commission Citation has been deleted.

Investigation Summary

Investigation Nr: 14197214
Event: 07/23/1984
ELECTRIC SHOCK - DIRECT CONTACT WITH WELDING ELECTRODE

AN EMPLOYEE USING A LINCOLN ARC WELDER (225 AMPERES; 75 VOLTS, OPEN-CIRCUIT VOLTAGE; 25 VOLTS, ARC VOLTAGE; SERIAL NO. 5683-701) WAS WELDING THE EXHAUST PIPE OF A CAR. HE WAS LYING ON HIS BACK ON A STEEL PLATE BENEATH THE CAR; THE GROUND WAS DAMP; AND HE WAS SWEATING. DURING THE WELDING OPERATION, THE EMPLOYEE WAS ELECTROCUTED. HE WAS A GRADUATE FROM A WELDING SCHOOL AND HAD BEEN EMPLOYED FOR TWO MONTHS. HE WAS NOT WEARING WELDING GLOVES AT THE TIME OF THE ACCIDENT.

Keywords: E GI III, AUTOMOTIVE REPAIR, ELECTRICAL, GLOVE, ELECTROCUTED, WELDING, ARC WELDING

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 14820047 Fatality Other Assemblers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.