Inspection: 14818264 - Mcgregor Printing Corp
Inspection Information - Office: Department Of Labor, Licensing, And Regulation Division Of Labor And Industry Maryland Occupational Safety And Health
Site Address:
Mcgregor Printing Corp
1241 New Windsor Rd
Westminster, MD 21157
Mailing Address:
2121 K St Nw, Washington, DC 20037
Union Status: NonUnion
SIC:2761
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/27/1984
Planning Guide: Safety-Manufacturing
Emphasis:
Case Closed: 11/29/1984
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360623748 |
Investigation Summary
An employee with 15 years experience and training as a press operator was operating an electric Hamilton collator (Serial No. 335120), one of his regularly assigned tasks. The collator created three-sheet forms with carbon between the sheets. It had stop-start buttons along its length, below the rollers, as well as a main control box. The employee was cleaning carbon residue from one set of power-driven rollers without deenergizing the machine. He was using a small rag in his right hand to perform this task. The rollers caught the rag and pulled in his fingers. Fortunately, he was able to pull his fingers free quickly. He was treated at a hospital for minor abrasions and temporary numbness and swelling. He returned to work approximately 1 hour after the accident. Company policy required that roller cleaning and any other machine maintenance to be performed with the machines off.
Keywords: FINGER, CLEANING, EMERGENCY STOP, ROLLER--MACH/PART, ABRASION, NIP POINT, PRESS OPERATOR
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 14818264 | Hospitalized injury | Bruise/Contus/Abras | Printing machine operators |