Inspection Detail
Inspection: 1480758.015 - Ford Motor Co.
Inspection Information - Office: Toledo Area Office
Site Address:
Ford Motor Co.
650 Miller Rd
Avon Lake, OH 44012
Mailing Address:
650 Miller Rd, Avon Lake, OH 44012
Union Status: Union
SIC:
NAICS: 336211/Motor Vehicle Body Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 06/24/2020
Emphasis: N:Amputate
Case Closed: 09/02/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1607433 | Yes |
Investigation Summary
At 4:00 p.m. on June 16, 2020, an employee working for an automobile manufacturer was tightening brackets in the trim shop in the final assembly area. The employee was tasked with fastening bolts down on the vehicle child tether bracket. It is still unknown exactly what happened; however, the employee was using a Bluetooth torque gun with her right hand on the bracket and left hand on the tool. As she attempted to torque the bolt down, her tear away glove may have caught on the edge of the bracket causing the glove to be pulled into the tool as the bracket rotated. An SOP exists for this job task and all torque guns were properly guarded. She pulled her right hand away and her glove tore allowing her to free her hand. EMS responded and transported the employee to the local hospital, where she was admitted to treat fractures and a dislocated index finger and cartilage tear of her middle finger.
Keywords: Assembling, Assembly Line, Automobile, Bolt, Bracket, Caught In, Dislocated, Finger, Fracture, Glove, Hand, Hand Tool, Misjudgment, Misjudgment of Hazardous Situation, Pinch Point, Pinched, Pulled In, Tear, Work Surface
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1480758.015 | 27 | F | Hospitalized injury |