Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1478467.015 - Dennen Steel Corporation

Inspection Information - Office: Miosha General Industry Safety & Health Division

 

Inspection Nr: 1478467.015
Report ID: 0552652
Date Opened: 06/26/2020

Site Address:
Dennen Steel Corporation
3033 Fruit Ridge Ave Nw
Grand Rapids, MI 49544

Mailing Address:
Po Box 3200, Grand Rapids, MI 49501

Union Status: NonUnion

SIC:

NAICS: 332116/Metal Stamping


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/13/2020

Emphasis: N:Amputate

Case Closed: 10/22/2020


Related Activity
Type Activity Nr Safety Health
Referral 1604641 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $4,800 $0 $0 $0 $0 $4,800
Current Penalty $2,400 $0 $0 $0 $0 $2,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 408.12193 09/18/2020 10/21/2020 $1,200 $2,400 $0 I - Informal Settlement  
2. 01001B Serious 408.12152(3) 09/18/2020 10/21/2020 $0 $0 $0 I - Informal Settlement  
3. 01002 Serious 408.10011 09/18/2020 10/21/2020 $1,200 $2,400 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 127325.015
Event: 05/18/2020
Employee is struck by equipment and incurs multiple injuries

At 8:15 p.m. on May 18, 2020, an employee was working as a technician for a metal stamping firm. He and a coworker were moving a Tinius Olsen tensile tester in the firm's quality lab through an aisle to a new location. The coworker had the tester on a Toyota powered industrial truck bearing the firm's property code #4 Maintenance. The tester assembly was 4 feet wide and 6 feet tall, and it weighed approximately 2,500 lbs. (1.2 meters wide and 1.8 meters tall, with a weight of 1,140 kg.). The tester assembly was not secured to the truck. The employee was spotting the movement. He was standing about 1 foot (0.3 meters) from the load. During the course of a normal truck movement, the Tinius Olsen tensile tester shifted and overturned. It fell onto the employee. The employee suffered a broken lower right leg, eight broken ribs, and a laceration to his forehead. He was hospitalized for two or more days.

Keywords: Broken Bone, Falling Object, Forehead, Fracture, Ind Trk Operator, Industrial Truck, Laceration, Leg, Load Shift, Powered Industrial Vehicle, Rib, Spotting, Struck By, Technician, Training, Unsecured, Unstable Load

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1478467.015 55 M Hospitalized injury Technicians, n.e.c.
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.