Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1476610.015 - Centrex Plastics, Llc

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 1476610.015
Report ID: 0524700
Date Opened: 05/27/2020

Site Address:
Centrex Plastics, Llc
814 W. Lima St.
Findlay, OH 45840

Mailing Address:
814 West Lima Street, Findlay, OH 45840

Union Status: NonUnion

SIC:

NAICS: 326199/All Other Plastics Product Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/27/2020

Emphasis: N:Amputate

Case Closed: 01/12/2021


Related Activity
Type Activity Nr Safety Health
Referral 1595638 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $26,988 $0 $0 $0 $0 $26,988
Current Penalty $13,494 $0 $0 $0 $0 $13,494
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01002A Serious 19100147 C07 I A 10/27/2020 11/05/2020 $13,494 $13,494 $0 I - Informal Settlement  
2. 01002B Serious 19100147 D 10/27/2020 11/05/2020 $0 $13,494 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 126488.015
Event: 05/21/2020
Employee's arm is crushed inside press

At 2:45 a.m. on May 21, 2020, Employee #1 was troubleshooting the Milacron Maxima Plastic Injection Press # 91 (Product # MPS-1100; Serial Number M7001AB010099). The parts were sticking inside the press because "air poppets froze up." Employee #1 went inside the press to "free poppets" with a brass hammer. Then, Employee #1 asked another a coworker to activate air inside the press. While Employee #1 was standing inside the press, and the doors of the press were closed, the coworker pushed the "mold close button" instead of the "air blow button." The mold inside the press closed, pinching the right arm of Employee #1. Employee #1 sustained a crushing injury of the right elbow; the elbow was removed, and a piece of metal connecting Employee #1's upper and lower arm was installed. Employee #1 was hospitalized.

Keywords: Arm, Crushed, Elbow, Hammer , Injection, Mold, Pinched, Press, Troubleshooting

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1476610.015 36 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.