Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1476505.015 - Bodycote

Inspection Information - Office: Long Beach District Office

 

Inspection Nr: 1476505.015
Report ID: 0950635
Date Opened: 05/12/2020

Site Address:
Bodycote
2900 S Sunol Dr
Vernon, CA 90058

Mailing Address:
2900 S Sunol Dr, Vernon, CA 90058

Union Status: NonUnion

SIC:

NAICS: 332811/Metal Heat Treating


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/07/2021

Emphasis:

Case Closed: 01/06/2022


Related Activity
Type Activity Nr Safety Health
Accident 1581279
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $50,000 $0 $0 $1,125 $0 $51,125
Current Penalty $23,400 $0 $0 $335 $0 $23,735
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 5162(A) 04/08/2021 05/13/2021 $335 $1,125 $0 04/27/2021 O - Administrative Law Judge Order  
2. 02001 Serious 3203(A)(4) 04/08/2021 05/13/2021 $18,000 $25,000 $0 04/27/2021 O - Administrative Law Judge Order  
3. 03001 Serious 3383(B) 04/08/2021 05/13/2021 $5,400 $25,000 $0 04/27/2021 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 129048.015
Event: 04/27/2020
Employee sustains multiple second degree burns when overcome

At 5:00 a.m. on April 27, 2020, an employee was working with a coworker, lubricating a chain on a Linberg RM03 Furnace, Model Number RO-72288. The employee was on top of the furnace to lubricate the chain, while the coworker was at the bottom using the controls to adjust the chain's movement. The employee was wearing a heat resistant uniform, dust mask, steel toe shoes and safety glasses. When the employee sprayed the chemical lubricant, he was overcome by fumes, causing him to fall unconscious onto the furnace. The employee received second degree burns to 5% of the thighs, groin and abdomen. The employee was hospitalized.

Keywords: Abdomen, Burn, Fall, Furnace, Groin, Lubricating, Maintenance, Overcome by vapors, Repair, Sprayed, Thigh, Unconsciousness

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1476505.015 48 M Hospitalized injury Furnace, kiln and oven operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.