Inspection: 1475309.015 - Pittsburg Tank & Tower Group

Inspection Information - Office: Dallas Area Office

 

Inspection Nr: 1475309.015
Report ID: 0626300
Date Opened: 05/14/2020

Site Address:
Pittsburg Tank & Tower Group
2661 Fm 2054
Tennessee Colony, TX 75886

Mailing Address:
P. O. Box 913, Henderson, KY 42419

Union Status: NonUnion

SIC:

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 07/02/2020

Emphasis:

Case Closed: 01/25/2021


Related Activity
Type Activity Nr Safety Health
Accident 1590188
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 1 1
Initial Penalty $18,892 $0 $0 $0 $0 $18,892
Current Penalty $0 $0 $0 $10,000 $0 $10,000
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19260057 C 10/28/2020 11/24/2020 $0 $6,747 $0 I - Informal Settlement Citation has been deleted.
2. 01001B Serious 19260057 F04 III 10/28/2020 11/24/2020 $0 $0 $0 I - Informal Settlement Citation has been deleted.
3. 01002A Other 19261211 A02 10/28/2020 11/24/2020 $10,000 $6,747 $0 I - Informal Settlement  
4. 01002B Serious 19261211 B01 10/28/2020 11/24/2020 $0 $0 $0 I - Informal Settlement Citation has been deleted.
5. 01003 Serious 19100134 H02 I 10/28/2020 11/24/2020 $0 $5,398 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 126277.015
Event: 05/14/2020
Employee collapses while painting inside of water storage ta

At 1:30 p.m. on May 14, 2000, an employee was painting the inside a 200,000 gallon potable water storage tank. At some point the employee collapsed and was rescued from the space by two coworkers who provided CPR until emergency medical services arrived. The employee died of Cardiomegaly which is an enlarged heart.

Keywords: CPR, Confined Space, Heart, Heart Attack, Painter, Spray Painting, Water Tank

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1475309.015 57 M Fatality Painters, construction and maintenance
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.